SMART Error Log Version: 1
ATA Error Count: 1
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 occurred at disk power-on lifetime: 5282 hours (220 days + 2 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
04 51 00 00 00 00 00 Error: ABRT
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
00 00 00 00 00 00 00 ff 11d+05:33:10.232 NOP [Abort queued commands]
b0 d4 00 82 4f c2 00 00 11d+05:32:50.043 SMART EXECUTE OFF-LINE IMMEDIATE
b0 d0 01 00 4f c2 00 00 11d+05:32:49.986 SMART READ DATA
ec 00 01 00 00 00 00 00 11d+05:32:49.976 IDENTIFY DEVICE
ec 00 01 00 00 00 00 00 11d+05:32:49.976 IDENTIFY DEVICE
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended captive Interrupted (host reset) 90% 5282 -
# 2 Conveyance offline Completed without error 00% 1463 -