Page Menu
Home
Phabricator
Search
Configure Global Search
Log In
Paste
P166
Masterwork From Distant Lands
Active
Public
Actions
Authored by
stwalkerster
on Dec 3 2017, 11:40 AM.
Edit Paste
Archive Paste
View Raw File
Subscribe
Mute Notifications
Tags
None
Referenced Files
F41627: Masterwork From Distant Lands
Dec 3 2017, 11:40 AM
2017-12-03 11:40:40 (UTC+0)
Subscribers
None
smartctl 6.5 2016-01-24 r4214 [x86_64-linux-4.4.0-101-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.14 (AF)
Device Model: ST2000DM001-1ER164
Serial Number: W4Z3V182
LU WWN Device Id: 5 000c50 09c18d96e
Firmware Version: CC26
User Capacity: 2,000,398,934,016 bytes [2.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sun Dec 3 11:40:38 2017 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 80) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 203) minutes.
Conveyance self-test routine
recommended polling time: ( 2) minutes.
SCT capabilities: (0x1085) SCT Status supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 114 099 006 Pre-fail Always - 78103176
3 Spin_Up_Time 0x0003 096 096 000 Pre-fail Always - 0
4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 16
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 063 060 030 Pre-fail Always - 2340384
9 Power_On_Hours 0x0032 094 094 000 Old_age Always - 5276
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 16
183 Runtime_Bad_Block 0x0032 099 099 000 Old_age Always - 1
184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0 0 3
189 High_Fly_Writes 0x003a 099 099 000 Old_age Always - 1
190 Airflow_Temperature_Cel 0x0022 068 056 045 Old_age Always - 32 (Min/Max 29/41)
191 G-Sense_Error_Rate 0x0032 100 100 000 Old_age Always - 0
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 7
193 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 2440
194 Temperature_Celsius 0x0022 032 044 000 Old_age Always - 32 (0 22 0 0 0)
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 6
240 Head_Flying_Hours 0x0000 100 253 000 Old_age Offline - 4898h+24m+47.954s
241 Total_LBAs_Written 0x0000 100 253 000 Old_age Offline - 7692273918
242 Total_LBAs_Read 0x0000 100 253 000 Old_age Offline - 30520245474
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Conveyance offline Completed without error 00% 1463 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
Event Timeline
stwalkerster
edited the content of this paste.
(Show Details)
Dec 3 2017, 11:40 AM
2017-12-03 11:40:40 (UTC+0)
stwalkerster
changed the title of this paste from untitled to
Masterwork From Distant Lands
.
stwalkerster
updated the paste's language from
autodetect
to
autodetect
.
stwalkerster
changed the visibility from "Subscribers" to "Public (No Login Required)".
Dec 3 2017, 11:41 AM
2017-12-03 11:41:16 (UTC+0)
Log In to Comment